TY - JOUR AU - Cekmecelioglu, Davut AU - Preventza, Ourania AU - Dougherty, Kathryn G. AU - Chatterjee, Subhasis AU - Green, Susan Y. AU - Silva, Guilherme V. AU - Díez, Jose G. AU - Coselli, Joseph S. PY - 2021 TI - Transcatheter valve-in-valve implantation for degenerated stentless aortic bioroots JF - Annals of Cardiothoracic Surgery; Vol 10, No 5 (September 29, 2021): Transcatheter Valve-in-Valve Y2 - 2021 KW - N2 - Background: Open surgical repair of a failed valve-sparing aortic root replacement (VSARR) or stentless bioroot aortic root replacement (bio-ARR) entails significant operative risks. Whether valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is feasible in patients with a previous VSARR or stentless bio-ARR remains unclear, given lingering concerns about the ill-defined aortic annulus in these patients and the potential for coronary obstruction. We present our experience with patients who had a previous VSARR or stentless bio-ARR and underwent ViV-TAVR to repair a degenerated aortic valve with combined valvular disease, aortic insufficiency and aortic stenosis. Methods: In this retrospective data review, we identified and analyzed consecutive patients with a previous VSARR or stentless bio-ARR who underwent ViV-TAVR between December 1, 2014 and August 31, 2019. Results: ViV-TAVR was performed in twelve high-risk patients with previous VSARR or bio-ARR during the study period. Of these, seven received Medtronic Freestyle porcine stentless bioprosthetic aortic roots, three received homograft aortic roots, one underwent a Ross procedure and one underwent VSARR. ViV-TAVR restored satisfactory valve function in all patients, and technical success was 100%. No patient had more than mild regurgitation after implantation. No thirty-day mortality was seen. One patient had major bleeding after transapical access, one patient had a transient ischemic stroke, and one patient needed permanent pacemaker implantation. At a median last follow-up of 21.5 months (interquartile range, 9.0–69.0 months), all patients remained alive and had satisfactory valve function. Conclusions: In this study, ViV-TAVR was a clinically effective option for treating patients with a failed stentless bio-ARR or previous VSARR. Short-term and intermediate-term results after these procedures were favorable. These findings may have important implications for treating high-risk patients with structural aortic root deterioration and call for better transcatheter heart valves that are suitable for treating aortic insufficiency. UR - https://www.annalscts.com/article/view/16859